WATERSAVERS "SAVINGS WITH COMFORT"
Settings & Installation for TOILETs
WC STOP
Configuration
- 5 rollers - flush from 0,5 litre – BASIC VERSION
By adding or removing rollers user can optimize the amount of flushed water according to their requirements. Removing rollers increases amount of flushed water.
Flushing can be set within the limits:
- Small flush: 0.5 - 3 litres
- Big flush: 9 - 10 litres
Set Up
Step 1: Remove a hanging unit from the knot.
Step 2: Remove or add demanded amount of cylinders.
Step 3: Put a hanging unit back to the knot.
Step 4: Automatic WC STOP is ready to be hanged.
Installation
WC STOP is placed in water tank, where is fixed on overflow tube.
Step 1: Remove hanging unit from an overflow tube.
Step 2: Insert and hang Automatic WC STOP into overflow tube.
Step 3: Put hanging unit back on the top of an overflow tube.
Step 4: Gently bend endpoints of WC STOP to provide fixation and steadiness.
Step 5: In case an oveflow tube contains lever, you can use it for regulation of WC STOP's effect.
Installation
Automatic WC STOP is easy to install even to toiletes with concealed cistern. Let's go through an installation guide, which will show you how easy is the installation process. We chose Geberit concealed flushing system as a learning tool.
If you wonder why you should install WC STOP to the flushing system, which is water-saving already, the answer is easy: user choose the most convenient way. In this case it is usage of a large button for a big flush. Over 75% users choose big flush without thinking - big button is just easier for their aim. Than a full cistern of water is used for flushing and there is no savings. Solution is the Automatic WC STOP.
Step 1: Remove a flush plate.
Step 2: Remove a covering case.
Move the white pins on both sides towards corners.
Loosen up side fixtures by twisting them and then remove. Remove the black case.
Twist the pins in the centre and remove.
Step 3: Removal of the white case.
Press the both buttons on sides, pull the case up and remove.
Step 4: Removal of the inner case.
Press the white buttons on both sides, push the case down and remove towards you.
Step 5: Removal of hold unit.
Press the white button in the centre, then remove.
Step 6: Installation of WC STOP.
Twist the fixation-part of flushing system and pull up.
Insert WC STOP into overflow tube (a big flush tube) and hang it. Return flushing system back to the place and twist back.
Step 7: Return all parts to the standard position by following the guide backward direction. Do not use force, all parts fit to each other easily.
Now you reached the maximal saving effect - water flows only when a user holds the big-flush button continuously. WC STOP shuts down a flush after the button is released. There is used adequate amount of water and not a whole cistern of water. Now you can enjoy the saving.
Please "Like
What makes WATERSAVERS unique?
EVERY
DROP
COUNTS
save water...
...save life